The PRC-A Series are improved versions of ULVAC's long-used PMB-003C(M), PMB-006C(M) and PMB-012C(M) models. They have the same evacuation performance with lower noise and greater reliability, and are ideal for use in the dust-sensitive environments required for clean rooms for semiconductor and LC manufacturing processes. The PRC-A Series are Roots pumps designed mainly for processes requiring highly clean atmospheres. They can be used with auxiliary pumps, to increase the evacuation speed in the 10 kPa to 1 Pa range.
|
Model
Item |
PRC-003A | PRC-006A | PRC-012A | ||
| Effective evacuation speed (m3/h (l/min)) (*1) |
50Hz | 330 | 520 | 930 | |
| 60Hz | 330 | 630 | 1000 | ||
| Final pressure (Pa) (*2) | 6.7 x10-1 | ||||
| Auxiliary pump | LR/HR60 | LR/HR90 | LR/HR90 | ||
| Maximum intake pressure (Pa) (except atmospheric pressure driven models) | 50Hz | 1.2 x 103 | 1.3 x 103 | 1.3 x 103 | |
| 60Hz | 9.3 x 102 | 1.1 x 103 | 1.1 x 103 | ||
| Maximum permitted pressure difference (Pa) (except atmospheric pressure driven models) | 50Hz | 4.0 x 103 | 7.3 x 103 | 7.3 x 103 | |
| 60Hz | 3.3 x 103 | 6.0 x 103 | 6.0 x 103 | ||
| Supported drive pressure (Pa) | Up to 1.0 x 105 (atmospheric pressure driven models only) | ||||
| Motor power (kW) (number of poles) (*3) | 0.75(2) | 2.2(2) | 3.7(2) | ||
| Oil (*4) | ULVOIL R-4 | ||||
| Required oil amount (l) | 0.7 | 1.5 | 1.9 | ||
| Cooling water | Cooling method | Water-cooled | |||
| Primary pressure (MPa) | 0.1 to 0.3 | ||||
| Outlet/inlet differential pressure (MPa) | 0.1< | ||||
| Flow rate (l/min) | 2.0< | 3.0< | |||
| Temperature (ºC) | 5 to 30 | ||||
| Intake size (JIS B 2290) | VG80 size | VG100 size | |||
| Vent size (JIS B 2290) | VF80 size | ||||
| External dimensions (L x W x H) (*5) | 296 x 565 x 260 | 356 x 619 x 320 | 406 x 759 x 340 | ||
| External dimensions of atmospheric pressure driven models | 296 x 651 x 260 | 366 x 740 x 20 | 426 x 911 x 340 | ||
| Weight (kg) (*6) | 51(54) | 86(90) | 118(123) | ||
Note :
This catalog uses SI measurement units. Conversion to non-SI units is as follows :
Final pressure : 6.7 x 10-1 Pa = 5.0 x 10-3 torr
Pressure : 0.1/0.2/0.3 MPa = 1/2/3 kgf/cm2
*1 Measured value at 13 Pa (Atmospheric pressure driven model)
*2 Measured by Pirani vacuum gauge (standard auxiliary pump and oil)
*3 200 VAC 50/60 Hz; 200 VAC 60 Hz; 3-phase
*4 When ordering oil, specify the type. Pump oil types other than the standard type are available. Contact ULVAC.
*5 W = width, D = depth, H = height
*6 Oil volume values in parentheses ( ) : For atmospheric pressure driven models
* Not available as explosion-proof type or increased safety type.